4 ADVANCED OPERATION EXAMPLE

APS-1102A

4-47

c) Operations after starting sequence

When a sequence is started, the status icon (

) is displayed in the status window to indicate that

the sequence is being executed. A message box is also displayed to indicate the step number being

executed.

After returning to the SET screen, if the sequence is executed, the current step settings will not be

shown in the SET screen. When the sequence is completed, the final step settings will be shown.

If the

final step voltage settings are outside of the setting range limit, both DC voltage and AC voltage will

be set to 0 V. If the final step frequency settings are outside of the setting range limit, frequency will be

set to the limit value of the setting range limit. In either case, the output will be turned off.

Status icon indicates that sequence
is being executed

Step number being executed

Figure 4-14. LCD Screen During Sequence Execution