beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 203

background image

6 REMOTE INTERFACE

APS-1102A

6-19

[SOURce:]CURRent:LIMit:AVErage

This sets the upper limit for the output RMS current. The output RMS current limiter setting

ranges from 1.0 A to 10.5 A (for 100 V range) or from 1.0 A to 5.3 A (for 200 V range). To keep

compatible with APS-1102, current average limiter command of APS-1102 can be used as RMS

limiter command of APS-1102A.

Syntax:

[SOURce:]CURRent:LIMit:AVErage

Parameter:

1.0 to 10.5 (1.0 to 5.3)

Command example:

CURR:LIM:AVE 5

Query example:

CURR:LIM:AVE ?

Response format:

Response example:

5.0

[SOURce:]CURRent:LIMit:PEAK:HIGH

This sets the upper limit of the output peak current (positive polarity). The output peak current

limiter (positive polarity) setting ranges from 10.0 A to 42.0 A (for 100 V range) or from 5.0 A to

21.0 A (for 200 V range).

Syntax:

[SOURce:]CURRent:LIMit:PEAK:HIGH

Parameters:

10.0 to 42.0 (5.0 to 21.0)

Command example:

CURR:LIM:PEAK:HIGH 10

Query example:

CURR:LIM:PEAK:HIGH?

Response format:

Response example:

10.0

[SOURce:]CURRent:LIMit:PEAK:LOW

This sets the upper limit for output peak current (negative polarity). The output peak current

limiter (negative polarity) setting ranges from

42.0 A to

10.0 A (for 100 V range) or from

21.0

A to

5.0 A (for 200 V range).

Syntax:

[SOURce:]CURRent:LIMit:PEAK:LOW

Parameters:

42.0 to

10.0(

21.0 to

5.0)

Command example:

CURR:LIM:PEAK:LOW

10

Query example:

CURR:LIM:PEAK:LOW?

Response format:

Response example:

10.0