beautypg.com

External control i/o, External interface, Power input – GW Instek APS-1102A User Manual User Manual

Page 280: 11 external control i/o

background image

APS-1102A User Manual

APS-1102A

9-14

9.11 External Control I/O

a) External control operation mode

Enabled or disabled (the state output is always on)

b) Control input

Input level:

High level: +4.0 V or higher

Low level: +1.0 V or lower

Nondestructive maximum input: +10 V/

5 V

Input impedance:

pull-up to +5 V at 47 k

Detection cycle:

2 ms

Control items:

Output off

Output off at fall

Output on

Output on at fall

Sequence start

Start at fall

Stop of sequence

Stop at fall

Hold input

Hold at fall

Branch inputs 0, 1

Start branch at fall

c) State output

Output level:

0 V/+5 V (open)

Output impedance:

100 Ω

Switching cycle:

0.1 ms

Status items:

Power source on/off status

L: off,

H: on

Output on/off status

L: off,

H: on

Limiter operation

L: Not operating, H: Operating

Software busy

L: Normal,

H: Busy

Sequence operation step synchronized outputs L or H

d) Terminals

D-sub 25-pin multi-connector

(rear panel, female, M2.6 screw)