GW Instek APS-1102A User Manual User Manual
Page 106

APS-1102A User Manual
APS-1102A
4-34
Table4-10. Setting Items in PROGRAM Screen (3/3)
Setting Name
Item
Operation
STEP TERM
Step end
Sets operation after end of step.
Select one of the following three options.
CONT:
Sequence continuation
STOP:
Change to Idle mode
HOLD:
Change to Hold mode
JUMP STEP
Jump step
Sets the step number to jump to after the end of the
previous step.
0:
Continue to next step number
1 to 255: Jump to specified step number
JUMP NUM
Jump times
Sets the number of times to execute the jump operation
specified by JUMP STEP.
0:
Infinite times jump
1 to 999: Specified times jump
BRANCH0
Branch step 0
Sets the step number to jump to when trigger input has
occurred.
Two types of branch steps can be set: BRANCH0 and
BRANCH1.
[Command example]
When a STOP is set after a small number of sweeps at the
jump destination step, it enables uses where there is a
safe region for saving data if necessary.
0:
Branch disabled
1 to 255: Jump to specified step number
BRANCH1
Branch step 1
The operation steps for each of the setting items in the PROGRAM screen are described below.
Operation step <1>
The settings for step number (STEP), step time (TIME), DC voltage (DC VOLT, AC+DC mode only),
AC voltage (AC VOLT), AC frequency (FREQ), phase (PHS), step end phase (STOP PHS), jump step
(JUMP STEP), jump times (JUMP NUM), and branch (BRANCH0/BRANCH1) are made by entering
numerical values for various items in the order described below.
The example described below is when entering the setting for step time (TIME).