GW Instek APS-1102A User Manual User Manual
Page 49
3 PANEL AND BASIC OPERATIONS
APS-1102A
3-15
3.3.5 External signal input/external sync signal input terminal
When using an externally input signal as the signal source with external synchronization, connect to the
external signal input/external sync signal input terminals (EXT SIG IN/EXT SYNC IN) on the rear panel.
For this connection, use a coaxial cable with a BNC connector.
The specifications for these external signal input/external sync signal input terminals are listed below.
Common specifications
Input terminal:
BNC connector (used for external signal input and external
sync signal input)
Input impedance:
10 kΩ
Non-destructive maximum input voltage:
10 V
External signal input
Frequency range:
DC to 550 Hz (sine wave)
DC to 100 Hz (other than sine wave)
Gain setting range:
100 V range:
0.0 times to 220.0 times (initial value is 100.0)
200 V range:
0.0 times to 440.0 times (initial value is 200.0)
Gain setting resolution:
0.1 times
Gain accuracy:
5% (DC or 45 Hz to 65 Hz, gain is at initial value, with
rated voltage output, no load)
Phase between input and output:
In-phase
Input voltage range:
2.2 V to +2.2 V
External synchronization
Synchronization frequency range:
40 Hz to 500 Hz
External sync signal is not required when line
synchronization is selected.
Input voltage threshold value:
TTL
Minimum pulse width
3 ms
External signal input/
external sync signal input
terminal
Figure 3-10. EXT SIG IN/EXT SYNC IN Terminal