Specifications

Table 6.6

Capacitance

Symbol

Parameter

Min

Max

Unit

Test Conditions

C

I

Input capacitance of input pads

7

pF

C

IO

Input capacitance of I/O pads

10

pF

Table 6.7

Output Signals

1

—MAC/_TESTOUT, REQ/

1. REQ/ has a 100

µ

A pull-up that is enabled when TESTIN is low.

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

OH

Output high voltage

2.4

V

DD

V

16 mA

V

OL

Output low voltage

V

SS

0.4

V

16 mA

I

OZ

3-state leakage

10

10

µ

A

Table 6.8

Output Signals

1

—IRQ/, SDIR[15:0], SDIRP0, SDIRP1, BSYDIR, SELDIR,

RSTDIR, TGS, IGS, MAS/[1:0], MCE/, MOE/, MWE/

1. IRQ/, MAS/[1:0], MCE/, MOE/, and MWE/ have a 100

µ

A pull-up that is enabled when TESTIN is

low. IRQ/ can be enabled with a register as an open drain with an internal 100

µ

A pull-up.

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

OH

Output high voltage

2.4

V

DD

V

4 mA

2

2. For IRQ/, Test Conditions are 8 mA.

V

OL

Output low voltage

V

SS

0.4

V

4 mA

2

I

OZ

3-state leakage

10

10

µ

A

Table 6.9

Output Signal—SERR/

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

OL

Output low voltage

V

SS

0.4

V

16 mA

I

OZ

3-state leakage

10

10

µ