Table 6.6 capacitance, Table 6.7 output signals—mac/_testout, req, Table 6.9 output signal—serr – Avago Technologies LSI53C825AE User Manual
Page 232: Capacitance, Output signals—mac/_testout, req, Output signal—serr

6-4
Specifications
Table 6.6
Capacitance
Symbol
Parameter
Min
Max
Unit
Test Conditions
C
I
Input capacitance of input pads
–
7
pF
–
C
IO
Input capacitance of I/O pads
–
10
pF
–
Table 6.7
Output Signals
1
—MAC/_TESTOUT, REQ/
1. REQ/ has a 100
µ
A pull-up that is enabled when TESTIN is low.
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
−
16 mA
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
–
Table 6.8
Output Signals
1
—IRQ/, SDIR[15:0], SDIRP0, SDIRP1, BSYDIR, SELDIR,
RSTDIR, TGS, IGS, MAS/[1:0], MCE/, MOE/, MWE/
1. IRQ/, MAS/[1:0], MCE/, MOE/, and MWE/ have a 100
µ
A pull-up that is enabled when TESTIN is
low. IRQ/ can be enabled with a register as an open drain with an internal 100
µ
A pull-up.
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
−
4 mA
2
2. For IRQ/, Test Conditions are 8 mA.
V
OL
Output low voltage
V
SS
0.4
V
4 mA
2
I
OZ
3-state leakage
−
10
10
µ
A
–
Table 6.9
Output Signal—SERR/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
–