Scsi interrupt status one (sist1), Scsi, Interrupt status one (sist1) – Avago Technologies LSI53C825AE User Manual
Page 165: Scsi interrupt status, One (sist1), Scsi interrupt status one, Sist1), Scsi interrupt, Status one (sist1)

Operating Registers
4-77
register) must be set for this bit to become active. The
LSI53C825A always generates parity when sending SCSI
data.
Register: 0x43 (0xC3)
SCSI Interrupt Status One (SIST1)
Read Only
Reading the
SCSI Interrupt Status One (SIST1)
register returns the
status of the various interrupt conditions, whether they are enabled in the
SCSI Interrupt Enable One (SIEN1)
register or not. Each bit that is set
indicates an occurrence of the corresponding condition.
Reading the SIST1 clears the interrupt condition.
R
Reserved
[7:3]
STO
Selection or Reselection Time-Out
2
The SCSI device which the LSI53C825A is attempting to
select or reselect does not respond within the
programmed time-out period. See the description of the
register, bits [3:0], for more
information on the time-out timer.
GEN
General Purpose Timer Expired
1
This bit is set when the general purpose timer expires.
The time measured is the time between enabling and
disabling of the timer. See the description of the
register, bits [3:0], for more
information on the general purpose timer.
HTH
Handshake-to-Handshake Timer Expired
0
This bit is set when the handshake-to-handshake timer
expires. The time measured is the SCSI Request to
Request (target) or Acknowledge-to-Acknowledge
(initiator) period. See the description of the
register, bits [7:4], for more information on
the handshake-to-handshake timer.
7
3
2
1
0
R
STO
GEN
HTH
x
x
x
x
x
0
0
0