beautypg.com

HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 89

background image

TNC 426/TNC 425/TNC 415 B/TNC 407

3-3

3

Test Run and Program Run

3.1

Test Run

ENT

e.g.

5

1 2 3

ENT

e.g.

ENT

1

e.g.

or

To run a program test up to a certain block:

With the STOP AT N function the TNC does a test run up to the block
with block number N.

Select the TEST RUN mode and go to the program beginning.

Select a partial test run.

STOP AT: N

=

PROGRAM

=

REPETITIONS

=

Enter the block number N at which you want the test to stop.

Enter the name of the program that contains block number N.

If N is located in a program section repeat, enter the number of
repeats that you want to run.

Test the program up to the entered block.

The display functions for test run

In the TEST RUN operating mode the TNC offers functions for displaying a
program in pages.

Shift the soft-key row.

Function

Soft key

Go back in the program by one screen

Go forward in the program by one screen

Go to the beginning of the program

Go to the end of the program