7.5 Checking and Changing Q Parameters

During a program run or program test, Q parameters can be checked and
changed if necessary.

Preparation:

• If you are in a program run, interrupt it (for example by pressing the

machine STOP key and the INTERNAL STOP soft key)

• If you are doing a test run, interrupt it

To call the Q parameter:

Q =

Select the parameter, for example Q10.

Q10 = + 100

The TNC displays the current value.

Change the Q parameter, for example Q10 = 0.

Leave the Q parameter unchanged.