beautypg.com

Transfer to the plc -19 – HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 208

background image

7-19

TNC 426/TNC 425/TNC 415 B/TNC 407

7

Programming with Q Parameters

Group name

Group No.

Number

Index System data

Active transformations

210

1

Basic rotation in MANUAL mode

2

Rotation programmed with Cycle 10

3

Active mirror axis
0: mirroring not active
+1: X axis mirrored
+2: Y axis mirrored
+4: Z axis mirrored
+8: IV axis mirrored
+16: V axis mirrored
Combinations = sum of individual axes

4

1

Active scaling factor in X axis

4

2

Active scaling factor in Y axis

4

3

Active scaling factor in Z axis

4

4

Active scaling factor in IV axis

4

5

Active scaling factor in V axis

5

1

3D ROT A axis

5

2

3D ROT B axis

5

3

3D ROT C axis

Example: Read a BASIC ROTATION from the MANUAL mode

and store it in Q25
D18 Q25 P01 210 P02 1

Transfer to the PLC

The function D19: PLC transfers up to two numerical values or
Q parameter contents to the PLC.

Increments and units: 0.1 µm or 0.0001°

Example D19 P01 +10 P02 +Q3

The numerical value 10 means 1 µm or 0.001°.

7.6