beautypg.com

HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 79

background image

TNC 426/TNC 425/TNC 415 B/TNC 407

2 - 1 8

2

Manual Operation and Setup

.

.

.

0

ENT

e.g.

END

0

ENT

1

e.g.

or

I

2.5

Setting the Datum with a 3D Touch Probe

DATUM

Enter the first coordinate of the datum (for example, in the X axis).

Select the second coordinate.

DATUM

Enter the second coordinate of the datum (for example, in the Y
axis).

Terminate the probing function.

Fig. 2.17: Probing the outside of a cylindrical

surface to find the center

Y

X

X–

X+

Y+

Y–

3

1

2

4

Outside circle

Move the touch probe to the starting position near the first touch point

(1) outside of the circle.

X + X – Y + Y –

Select the probing direction.

Probe the workpiece.

Repeat the probing process for points 2, 3 and 4 (see illustration).

Enter the coordinates of the datum.

After the probing procedure is completed, the TNC displays the
coordinates of the circle center and the circle radius PR.