beautypg.com

Blockwise transfer -6 – HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 284

background image

9-6

9

External Data Transfer

TNC 426/TNC 425/TNC 415 B/TNC 407

9.2

Data Transfer with the TNC 425, TNC 415 B and TNC 407

When aborting blockwise transfer, you may have to reset the interface with the CLOSE RS-232-C soft key.

Fig. 9.1:

Menu for blockwise transfer

Transferring files from an external device to the TNC

Use the cursor key to move the highlight to a file that is stored in the
external device.

Function

Soft key

Transfer selected file

Transfer all files

Select files consecutively for individual
transfer. Press ENT to transfer,
otherwise press NO ENT

Interrupt transfer

You can interrupt data transfer by pressing the END key or the END soft
key.

• If the TNC recognizes erroneously transferred program blocks, it will mark them with ERROR =.

These blocks must then be corrected in the PROGRAMMING AND EDITING mode.

• If you want to transfer files between two TNCs, start transmission from the receiving TNC.

Blockwise transfer

The menu to the right is for blockwise transfer (see
page 3-11). First select as usual the name of the file
to be transferred blockwise. Then start data
transfer with the SELECT soft key.