beautypg.com

Tnc displays, tnc editor -7 – HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 304

background image

11-7

11

Tables, Overviews and Diagrams

TNC 426/TNC 425/TNC 415 B/TNC 407

TNC displays, TNC editor

11.1 General User Parameters

If a particular file type is inhibited, all files of this type will be erased.

Programming station

MP7210

TNC with machine:

0

TNC as programming station with active PLC:

1

TNC as programming station with inactive PLC:

2

Acknowledgment of POWER INTERRUPTED message after switch-on

MP7212

Acknowledge with key:

0

Acknowledge automatically:

1

ISO programming: Block number increment

MP7220

0 to 150

Length of file names

MP7222

Maximum 8 characters:

0

Maximum 12 characters:

1

Maximum 16 characters:

2

Inhibit particular file types

MP7224.0

Do not inhibit file types:

+0

Inhibit HEIDENHAIN programs:

+1

Inhibit ISO programs:

+2

Inhibit tool tables:

+4

Inhibit datum tables:

+8

Inhibit pallet tables:

+16

Inhibit text files:

+32

Inhibit PNT tables:

+128

Inhibit the editor for certain file types

MP7224.1

Do not inhibit editor:

+0

Inhibit editor for HEIDENHAIN programs:

+1

Inhibit editor for ISO programs:

+2

Inhibit editor for tool tables:

+4

Inhibit editor for datum tables:

+8

Inhibit editor for pallet tables:

+16

Inhibit editor for text files:

+32

Inhibit editor for PNT tables:

+128

426