Tnc displays, tnc editor -7 – HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual
Page 304
11-7
11
Tables, Overviews and Diagrams
TNC 426/TNC 425/TNC 415 B/TNC 407
TNC displays, TNC editor
If a particular file type is inhibited, all files of this type will be erased.
Programming station
MP7210
TNC with machine:
0
TNC as programming station with active PLC:
1
TNC as programming station with inactive PLC:
2
Acknowledgment of POWER INTERRUPTED message after switch-on
MP7212
Acknowledge with key:
0
Acknowledge automatically:
1
ISO programming: Block number increment
MP7220
0 to 150
Length of file names
MP7222
Maximum 8 characters:
0
Maximum 12 characters:
1
Maximum 16 characters:
2
Inhibit particular file types
MP7224.0
Do not inhibit file types:
+0
Inhibit HEIDENHAIN programs:
+1
Inhibit ISO programs:
+2
Inhibit tool tables:
+4
Inhibit datum tables:
+8
Inhibit pallet tables:
+16
Inhibit text files:
+32
Inhibit PNT tables:
+128
Inhibit the editor for certain file types
MP7224.1
Do not inhibit editor:
+0
Inhibit editor for HEIDENHAIN programs:
+1
Inhibit editor for ISO programs:
+2
Inhibit editor for tool tables:
+4
Inhibit editor for datum tables:
+8
Inhibit editor for pallet tables:
+16
Inhibit editor for text files:
+32
Inhibit editor for PNT tables:
+128
426