background image

11-5

11

Tables, Overviews and Diagrams

TNC 426/TNC 425/TNC 415 B/TNC 407

3D touch probes and digitizing

MP6300

Reserved

Infeed of the stylus when digitizing with a measuring touch probe

MP6310

0.1 to 2.0000 [mm] (recommended input value: 1mm)

Measure center misalignment of the stylus when calibrating a measuring touch probe

MP6321

Measure center misalignment:

0

Do not measure center misalignment:

1

Assign touch probe axis to machine axis for a measuring touch probe

MP6322.0

Machine X axis parallel to
Touch probe X axis:

0

Touch probe Y axis:

1

Touch probe Z axis:

2

MP6322.1

Machine Y axis parallel to
Touch probe X axis:

0

Touch probe Y axis:

1

Touch probe Z axis:

2

MP6322.2

Machine Z axis parallel to
Touch probe X axis:

0

Touch probe Y axis:

1

Touch probe Z axis:

2

Maximum stylus deflection on measuring touch probes

MP6330

0.1 to 4.0000 [mm]

Feed rate for positioning measuring touch probes at MIN point and approaching contour

MP6350

10 to 3 000 [mm/min]

Probing feed rate for measuring touch probes

MP6360

10 to 3 000 [mm/min]

Rapid traverse for measuring touch probes in the probe cycle

MP6361

10 to 3 000 [mm/min]

Feed rate decrease when the stylus of a measuring touch probe is deflected to the side

The TNC decreases the feed rate according to a preset characteristic curve. The
minimum input value is 10% of the programmed digitizing feed rate.

MP6362

Feed rate decrease not active:

0

Feed rate decrease active:

1

Target window for digitizing contour lines with measuring touch probes

When you are digitizing contour lines the individual contour lines do not end exactly in their starting points. With
machine parameter MP 6390 you can define a square target window within which the end point must lie after
the touch probe has orbited the model. Enter half the side length of the target window for the input value.

MP6390

0.1 to 4.0000 [mm]

11.1 General User Parameters

Ensure that the touch probe axes are correctly assigned to the machine axes. Wrong assignment could lead
to a stylus break.