beautypg.com

Preparing the devices for data transfer -10, Heidenhain devices -10 non-heidenhain devices -10, 4 preparing the devices for data transfer – HEIDENHAIN TNC 407 (280 580) ISO Programming User Manual

Page 288

background image

9-10

9

External Data Transfer

TNC 426/TNC 425/TNC 415 B/TNC 407

9.4

Preparing the Devices for Data Transfer

HEIDENHAIN devices

HEIDENHAIN devices (FE floppy disk unit and ME magnetic tape unit) are
already adapted to the TNC. They can be used for data transfer without
further adjustments.

Example: FE 401 floppy disk unit

• Connect the power cable to the FE
• Connect the FE and TNC with the data interface cable
• Switch on the FE
• Insert a diskette into the upper drive
• Format the diskette if necessary
Set the interface (see page 10-4)
• Transfer the data

• The memory capacity of a floppy disk is given in sectors.

• The baud rate can be set at the FE 401.

Non-HEIDENHAIN devices

The TNC and non-HEIDENHAIN devices must be adapted to each other.

To adapt a non-HEIDENHAIN device to the TNC

• PC: Adapt the software
• Printer: set the DIP switches

To adapt the TNC to a non-HEIDENHAIN device

Set the user parameters:

• 5020.0 to 5210.0 for EXT1
• 5020.1 to 5210.1 for EXT2

The two settings can be adjusted, for example, to a PC (e.g. EXT1) or to a
printer (EXT2).