beautypg.com

Delta Electronics Human Machine Interface DOP-A Series User Manual

Page 252

background image

Chapter 4 Macro Function|ScrEdit Software User Manual

Revision Apr. 30th, 2007, 2007PDD23000002

4-31

However, in the sub-macro program, the user can call another sub-macro program but the

levels for calling sub-macro should be less than 6 levels.

CALL

RET

Main

Macro

Sub-Macro

A1

Fig. 4.3.1

„

FOR…NEXT

Program Loop

Equation:

FOR V1

Statement

NEXT

It is for multi-level loops. The multi-level loop can be up to 3 levels. V1 can be the internal memory or

constant. When this command is executed, the number of V1 Statement can be executed continuously.

Statement is the combination of a section of macro commands.

Example:

$10 = 10

$1 = 0

FOR $10

$1 = $1 + 1

$10 = 2

NEXT

After the operation, the result is $1 = 10, $10 = 2.

Please note that the loop times will not change even if the user resets the value within $10.

„

END

End the macro

Equation:

Statements1

END

Statements2