Lldp notification-interval, Lldp notification, Interval – Microsens MS453490M Management Guide User Manual
Page 885

C
HAPTER
38
| LLDP Commands
– 885 –
D
EFAULT
S
ETTING
Holdtime multiplier: 4
TTL: 4*30 = 120 seconds
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
The time-to-live tells the receiving LLDP agent how long to retain all
information pertaining to the sending LLDP agent if it does not transmit
updates in a timely manner.
E
XAMPLE
Console(config)#lldp holdtime-multiplier 10
Console(config)#
lldp notification-
interval
This command configures the allowed interval for sending SNMP
notifications about LLDP MIB changes. Use the no form to restore the
default setting.
S
YNTAX
lldp notification-interval seconds
no lldp notification-interval
seconds - Specifies the periodic interval at which SNMP notifications
are sent. (Range: 5 - 3600 seconds)
D
EFAULT
S
ETTING
5 seconds
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
◆
This parameter only applies to SNMP applications which use data stored
in the LLDP MIB for network monitoring or management.
◆
Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the
time of a notification are included in the transmission. An SNMP agent
should therefore periodically check the value of
lldpStatsRemTableLastChangeTime to detect any lldpRemTablesChange
notification-events missed due to throttling or transmission loss.
E
XAMPLE
Console(config)#lldp notification-interval 30
Console(config)#