Parity 523, Parity – Microsens MS453490M Management Guide User Manual
Page 523

C
HAPTER
21
| System Management Commands
Line
– 523 –
D
EFAULT
S
ETTING
login local
C
OMMAND
M
ODE
Line Configuration
C
OMMAND
U
SAGE
◆
There are three authentication modes provided by the switch itself at
login:
■
login selects authentication by a single global password as
specified by the
line configuration command. When using
this method, the management interface starts in Normal Exec (NE)
mode.
■
login local selects authentication via the user name and password
specified by the
command (i.e., default setting). When
using this method, the management interface starts in Normal Exec
(NE) or Privileged Exec (PE) mode, depending on the user’s
privilege level (0 or 15 respectively).
■
no login selects no authentication. When using this method, the
management interface starts in Normal Exec (NE) mode.
◆
This command controls login authentication via the switch itself. To
configure user names and passwords for remote authentication
servers, you must use the RADIUS or TACACS software installed on
those servers.
E
XAMPLE
Console(config-line)#login local
Console(config-line)#
R
ELATED
C
OMMANDS
parity
This command defines the generation of a parity bit. Use the no form to
restore the default setting.
S
YNTAX
parity {none | even | odd}
no parity
none - No parity
even - Even parity
odd - Odd parity