Port mirroring commands, Local port mirroring commands, 29 p – Microsens MS453490M Management Guide User Manual
Page 727: Irroring, Ommands, Port monitor, Table 93: port mirroring commands, Table 94: mirror port commands

– 727 –
29
P
ORT
M
IRRORING
C
OMMANDS
Data can be mirrored from a local port on the same switch or from a
remote port on another switch for analysis at the target port using
software monitoring tools or a hardware probe. This switch supports the
following mirroring modes.
L
OCAL
P
ORT
M
IRRORING
C
OMMANDS
This section describes how to mirror traffic from a source port to a target
port.
port monitor
This command configures a mirror session. Use the no form to clear a
mirror session.
S
YNTAX
port monitor {interface [rx | tx | both] | vlan vlan-id |
mac-address mac-address}
no port monitor interface
interface - ethernet unit/port (source port)
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10)
rx - Mirror received packets.
tx - Mirror transmitted packets.
both - Mirror both received and transmitted packets.
vlan-id - VLAN ID (Range: 1-4093)
Table 93: Port Mirroring Commands
Command
Function
Mirrors data to another port for analysis without affecting the data
passing through or the performance of the monitored port
Mirrors data from remote switches over a dedicated VLAN
Table 94: Mirror Port Commands
Command
Function
Mode
Configures a mirror session
IC
Shows the configuration for a mirror port
PE