silent-time

This command sets the amount of time the management console is

inaccessible after the number of unsuccessful logon attempts exceeds the

threshold set by the

password-thresh

command. Use the no form to

remove the silent time value.

S

YNTAX

silent-time [seconds]
no silent-time

seconds - The number of seconds to disable console response.

(Range: 0-65535; 0: 30 seconds)

D

EFAULT

S

ETTING

The default value is no silent-time.

C

OMMAND

M

ODE

Line Configuration

E

XAMPLE

To set the silent time to 60 seconds, enter this command:

Console(config-line)#silent-time 60

Console(config-line)#

R

ELATED

C

OMMANDS

password-thresh (525)

speed

This command sets the terminal line’s baud rate. This command sets both

the transmit (to terminal) and receive (from terminal) speeds. Use the no

form to restore the default setting.

S

YNTAX

speed bps
no speed

bps - Baud rate in bits per second.

(Options: 9600, 19200, 38400, 57600, 115200 bps, or auto)

D

EFAULT

S

ETTING

115200 bps

C

OMMAND

M

ODE

Line Configuration

C

OMMAND

U

SAGE

Set the speed to match the baud rate of the device connected to the serial

port. Some baud rates available on devices connected to the port might not

be supported. The system indicates if the speed you selected is not