Silent-time 526 speed 526, Silent-time, Speed – Microsens MS453490M Management Guide User Manual
Page 526: Silent-time (526)

C
HAPTER
21
| System Management Commands
Line
– 526 –
silent-time
This command sets the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts exceeds the
threshold set by the
command. Use the no form to
remove the silent time value.
S
YNTAX
silent-time [seconds]
no silent-time
seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: 30 seconds)
D
EFAULT
S
ETTING
The default value is no silent-time.
C
OMMAND
M
ODE
Line Configuration
E
XAMPLE
To set the silent time to 60 seconds, enter this command:
Console(config-line)#silent-time 60
Console(config-line)#
R
ELATED
C
OMMANDS
speed
This command sets the terminal line’s baud rate. This command sets both
the transmit (to terminal) and receive (from terminal) speeds. Use the no
form to restore the default setting.
S
YNTAX
speed bps
no speed
bps - Baud rate in bits per second.
(Options: 9600, 19200, 38400, 57600, 115200 bps, or auto)
D
EFAULT
S
ETTING
115200 bps
C
OMMAND
M
ODE
Line Configuration
C
OMMAND
U
SAGE
Set the speed to match the baud rate of the device connected to the serial
port. Some baud rates available on devices connected to the port might not
be supported. The system indicates if the speed you selected is not