Databits 521, Databits – Microsens MS453490M Management Guide User Manual
Page 521

C
HAPTER
21
| System Management Commands
Line
– 521 –
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
Telnet is considered a virtual terminal connection and will be shown as
“VTY” in screen displays such as
. However, the serial
communication parameters (e.g., databits) do not affect Telnet
connections.
E
XAMPLE
To enter console line mode, enter the following command:
Console(config)#line console
Console(config-line)#
R
ELATED
C
OMMANDS
databits
This command sets the number of data bits per character that are
interpreted and generated by the console port. Use the no form to restore
the default value.
S
YNTAX
databits {7 | 8}
no databits
7 - Seven data bits per character.
8 - Eight data bits per character.
D
EFAULT
S
ETTING
8 data bits per character
C
OMMAND
M
ODE
Line Configuration
C
OMMAND
U
SAGE
The databits command can be used to mask the high bit on input from
devices that generate 7 data bits with parity. If parity is being generated,
specify 7 data bits per character. If no parity is required, specify 8 data bits
per character.
E
XAMPLE
To specify 7 data bits, enter this command:
Console(config-line)#databits 7
Console(config-line)#