Table 9: recommended sta path cost range, Table 10: recommended sta path costs, Table 11: default sta path costs – Microsens MS453490M Management Guide User Manual
Page 204
C
HAPTER
8
| Spanning Tree Algorithm
Configuring Interface Settings for STA
– 204 –
port priority. (Range: 0 for auto-configuration, 1-65535 for the short
path cost method
3
, 1-200,000,000 for the long path cost method)
By default, the system automatically detects the speed and duplex
mode used on each port, and configures the path cost according to the
values shown below. Path cost “0” is used to indicate auto-configuration
mode. When the short path cost method is selected and the default
path cost recommended by the IEEE 8021w standard exceeds 65,535,
the default is set to 65,535.
◆
Admin Link Type – The link type attached to this interface.
■
Point-to-Point – A connection to exactly one other bridge.
■
Shared – A connection to two or more bridges.
■
Auto – The switch automatically determines if the interface is
attached to a point-to-point link or to shared media. (This is the
default setting.)
3. Refer to
"Configuring Global Settings for STA" on page 197
for information on setting
the path cost method.
Table 9: Recommended STA Path Cost Range
Port Type
IEEE 802.1D-1998
IEEE 802.1w-2001
Ethernet
50-600
200,000-20,000,000
Fast Ethernet
10-60
20,000-2,000,000
Gigabit Ethernet
3-10
2,000-200,000
Table 10: Recommended STA Path Costs
Port Type
Link Type
IEEE 802.1D-1998
IEEE 802.1w-2001
Ethernet
Half Duplex
Full Duplex
Trunk
100
95
90
2,000,000
1,999,999
1,000,000
Fast Ethernet
Half Duplex
Full Duplex
Trunk
19
18
15
200,000
100,000
50,000
Gigabit Ethernet
Full Duplex
Trunk
4
3
10,000
5,000
Table 11: Default STA Path Costs
Port Type
IEEE 802.1D-1998
IEEE 802.1w-2001
Ethernet
Half Duplex
Full Duplex
Trunk
2,000,000
1,000,000
500,000
Fast Ethernet
Half Duplex
Full Duplex
Trunk
200,000
100,000
50,000
Gigabit Ethernet
Full Duplex
Trunk
10,000
5,000