Table 22: logging levels – Microsens MS453490M Management Guide User Manual
Page 352
C
HAPTER
15
| Basic Administration Protocols
Configuring Event Logging
– 352 –
P
ARAMETERS
These parameters are displayed:
◆
System Log Status – Enables/disables the logging of debug or error
messages to the logging process. (Default: Enabled)
◆
Flash Level – Limits log messages saved to the switch’s permanent
flash memory for all levels up to the specified level. For example, if
level 3 is specified, all messages from level 0 to level 3 will be logged to
flash. (Range: 0-7, Default: 3)
◆
RAM Level – Limits log messages saved to the switch’s temporary RAM
memory for all levels up to the specified level. For example, if level 7 is
specified, all messages from level 0 to level 7 will be logged to RAM.
(Range: 0-7, Default: 7)
N
OTE
:
The Flash Level must be equal to or less than the RAM Level.
W
EB
I
NTERFACE
To configure the logging of error messages to system memory:
1.
Click Administration, Log, System.
2.
Select Configure Global from the Step list.
3.
Enable or disable system logging, set the level of event messages to be
logged to flash memory and RAM.
4.
Click Apply.
Table 22: Logging Levels
Level
Severity Name
Description
7
Debug
Debugging messages
6
Informational
Informational messages only
5
Notice
Normal but significant condition, such as cold
start
4
Warning
Warning conditions (e.g., return false,
unexpected return)
3
Error
Error conditions (e.g., invalid input, default used)
2
Critical
Critical conditions (e.g., memory allocation, or
free memory error - resource exhausted)
1
Alert
Immediate action needed
0
Emergency
System unusable