Stopbits 527 timeout login response, Stopbits, Timeout login response – Microsens MS453490M Management Guide User Manual
Page 527
C
HAPTER
21
| System Management Commands
Line
– 527 –
supported. If you select the “auto” option, the switch will automatically
detect the baud rate configured on the attached terminal, and adjust the
speed accordingly.
E
XAMPLE
To specify 57600 bps, enter this command:
Console(config-line)#speed 57600
Console(config-line)#
stopbits
This command sets the number of the stop bits transmitted per byte. Use
the no form to restore the default setting.
S
YNTAX
stopbits {1 | 2}
no stopbits
1 - One stop bit
2 - Two stop bits
D
EFAULT
S
ETTING
1 stop bit
C
OMMAND
M
ODE
Line Configuration
E
XAMPLE
To specify 2 stop bits, enter this command:
Console(config-line)#stopbits 2
Console(config-line)#
timeout login
response
This command sets the interval that the system waits for a user to log into
the CLI. Use the no form to restore the default setting.
S
YNTAX
timeout login response [seconds]
no timeout login response
seconds - Integer that specifies the timeout interval.
(Range: 0 - 300 seconds; 0: disabled)
D
EFAULT
S
ETTING
CLI: Disabled (0 seconds)
Telnet: 300 seconds