beautypg.com

Oduflex – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 629

background image

Glossary

SONET/SDH Application

615

G.709 Optical Transport Network (OTN)

ODUflex

ODUflex provides the capability to carry client payload of variable size with
a container size of 1.244 Gb/s granularity. An ODUflex (L) signal can be
transported once multiplexed in an ODUk (H) signal, the multiplexer in
this case handles tributary slots of 1.244 Gb/s and has a Payload Type 21.
The ODUflex function can be used to transport 2 signal categories mapped
in ODTUk.ts using GMP:

³

Ethernet in ODUflex over GFP-F signal

The Ethernet packets are mapped in GFP-F as specified in G.7041, the
packets are processed as follows:

³

The Start of Frame Delineation bytes are terminated

³

Inter Frame Gaps bytes are terminated

³

PCS coding is terminated

³

GFP overhead bytes added

Since the PCS coding is terminated, it is not possible to transport the
Ethernet Link status transparently but it is accommodated by the
Forward Defect Indication (FDI) and Remote Defect Indication (RDI)
alarms over GFP. The RDI is used to carry the Remote Fault alarm
while the FDI is used to carry the Local Fault.

GFP-F provides rate adaptation between the incoming Ethernet signal
and the outgoing OPUflex transport signal. This brings the fact that
GMP is operated at a fixed Cm value close to the maximum server
capacity.

³

CBR over ODUflex signal

ODUflex can transport Constant Bit Rate signal (bulk filled Test pattern)
as Client of the ODUflex CBR function. This CBR function needs a
Pattern generator that can operate at a data rate specified by the user,
the range of the available data rates is qualified by the Bandwidth
management function.