background image

Creating and Starting a Test Case

SONET/SDH Application

87

Typical Test Cases

Creating an Optical SONET/SDH Test Case on an
IQS-8140

To create an Optical SONET/SDH Test on an IQS-8140:
1.
Test configuration:

1a. Select the source Clock Mode that will be used

for the test. Refer to Clock Configuration on
page 129 for more information.

1b. Select Normal as the Test Mode. Refer toTest

Configuration on page 126 for more
information.

1c. Select the Coupled check box to set the same

settings for both the TX and RX signals or clear the Coupled
check box to configure the TX and RX signal individually
(decoupled).

1d. Select the Through check box to loop the RX signal to the TX port.

The Clock Mode is automatically set to Recovered when the
Through check box is selected.

1e. Select the SONET/SDH Intrusive check box to loop the RX signal

to the TX port with TX overwrite capabilities.

1f. Leave the OTN Intrusive check box cleared.

1g. Press Next.