beautypg.com

EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 258

background image

SONET Tabs

244

IQS-8100 Series Transport Blazer

APS/Advanced Line OH TX/RX (SONET)

S1

³

Overwrite: The Overwrite check box when selected, allows the
generation of the selected S1 bits. Overwrite is available with
SONET/SDH Intrusive mode only.

³

Bits 1-4: Bits 1 through 4 of the S1 byte are currently undefined but can
be set from 0000 to 1111 if required.

³

Bits 5-8 (Synchronization Status Message): Bits 5 through 8 of the S1
byte are used to convey synchronization status of the NE. The default
setting is Synchronized - Traceability Unknown (0000). Choices are:

Bits

5 to 8

Description

Bits

5 to 8

Description

0000

Synchronized - Traceability

Unknown

1000

Reserved

0001

Stratum 1 Traceable

1001

Reserved

0010

Reserved

1010

Stratum 3 Traceable

0011

Reserved

1011

Reserved

0100

Transit Node Clock Traceable 1100

SONET Minimum Clock Traceable

0101

Reserved

1101

Stratum 3E Traceable

0110

Reserved

1110

Provisionable by the Network Operator

0111

Stratum 2 Traceable

1111

Don’t Use for Synchronization