SDH Tabs

350

IQS-8100 Series Transport Blazer

LOP TX (SDH)

Alarm Generation

Allows Continuous or Burst alarm generation methods.

³

Type: The following errors are available:

TU-AIS (Tributary Unit - Alarm Indication Signal): Generates an all-ones
pattern for the V1 and V2 bytes of the TU path and payload.

LP-RDI (Low Order Path - Remote Defect Indication): Generates “1”
for the bit 8 of the V5 byte and a “00” pattern for bits 6 and 7 of the K4
byte.

ERDI-SD (Enhanced RDI - Server Defect): Generates a 101 pattern for
bits 5, 6, and 7 of the K4 byte, and 1 for bit 8 of the V5 byte.

ERDI-CD (Enhanced RDI - Connectivity Defect): Generates a 110
pattern for bits 5, 6, and 7 of the K4 byte, and 1 for bit 8 of the V5 byte.

ERDI-PD (Enhanced RDI - Path Payload Defect): Generates a “010”
pattern for bits 5, 6, and 7 of the K4 byte, and “0” for bit 8 of the V5 byte.

LP-RFI (Low Order Path - Remote Failure Indication) (available with
VC-11 only): Generates “1” for the bit 4 of the V5 byte.

TU-LOP (Tributary Unit - Loss of Pointer): Generates a non-valid
pointer.

LP-UNEQ (Low Order Path - Unequipped): Generates unequipped LP
signal label (bits 5 through 7 of V5 byte are set to “000”).