beautypg.com

Far-end – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 524

background image

Common Tabs

510

IQS-8100 Series Transport Blazer

Performance Monitoring (PM)

Far-End

³

EFS (Error Free Second): Gives the count of the seconds within which
no error occurred or when a defect is detected on the near-end.

³

EC (Error Count) (G.821 only): Gives the number of bit errors.

³

EB (Errored Block) (G.826, G.828, and G.829): Gives the count of
blocks in which one or more bits are in error.

³

ES (Errored Second): For G.826, G.828, G.829, M.2100 ISM, and
M.2101: Gives the count of the seconds within which one or more
anomalies (FAS, EB, etc.) occurred or at least one defect occurred.

³

SES (Severely Errored Second):

For G.826, G.828, G.829, and M.2101: Gives the count of the seconds
within which anomalies (FAS, EB, etc.) is ≥ X% or at least one defect
occurred. X = 30% for DSn/PDH signals; see the following table for
SONET/SDH signals.

STS-1

STM-0

OC-3

STM-1

OC-12

STM-4

OC-48

STM-16

OC-192

STM-64

OC-768

STM-256

Path

30%

30%

30%

30%

30%

30%

Line/MS

15%

15%

25%

30%

30%

30%

Section/RS 10%

30%

30%

30%

30%

30%