Lcas source - configuration, Remote dut, Alarm – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 493

background image

Next-Generation Tabs

SONET/SDH Application

479

LCAS - Source

LCAS Source - Configuration

Press TEST, LCAS and Configuration (under LCAS Source).

Note: Not available in Through mode.

³

Member indicates the timeslot number.

³

Auto Add at Startup: Allows enabling the members that will be
automatically added (applied) when the test is started.

Remote DUT

Non-LCAS: Specifies that the remote device connected to the IQS-8100
Series is LCAS (when disabled) or Non-LCAS (when enabled). Remote
DUT, when Non-LCAS is enabled, is used to test the interoperability
between an LCAS and a VCAT device that does not support LCAS.

Alarm

Note: Not available when Non-LCAS from the Remote DUT group is enabled.

PLCT Threshold (Partial Loss of Capacity Transmit Threshold): Allows the
selection of the PLCT threshold value. Choices are from 1 to the
provisioned member minus 1. The default setting is 1.