Creating and Starting a Test Case

SONET/SDH Application

97

Typical Test Cases

Creating an OTN (OTU3) Test Case

To create an OTN Test on an IQS-8140 module:
1.
Test configuration:

1a. Select the source Clock Mode that will be used

for the test. Refer to Clock Configuration on
page 129 for more information.

1b. Select Normal as the Test Mode. Refer toTest

Configuration on page 126 for more
information.

1c. Select the Coupled check box to set the same

settings for both the TX and RX signals or clear the Coupled
check box to configure the TX and RX signal individually
(decoupled).

1d. Select the Through check box to loop the RX signal to the TX port.

The Clock Mode is automatically set to Recovered when the
Through check box is selected.

1e. Select the OTN Intrusive check box to loop the RX signal to the

TX port with TX overwrite capabilities. Available when the
Coupled check box is selected.

1f. Leave the SONET/SDH Intrusive check box cleared.

1g. Press Next.