Port Tabs

SONET/SDH Application

143

Port RX (Electrical Interfaces)

Alarm Analysis

Possible alarms that can be detected are:

³

LOS (Loss Of Signal): The LOS alarm indicates absence of an input
signal or an all-zeros pattern was detected.

³

Frequency: The frequency alarm indicates if the received signal rate
meets the standard rate specifications (green) or not (red).

Interface

Standard Rate Specification

DS1

1544000 ±57 bps (±36.6 ppm)

E1

2048000 ±112 bps (±54.6 ppm)

E2

8448000 ±293 bps (±34.6 ppm)

E3

34368000 ±846 bps (±24.6 ppm)

DS3

44736000 ±1101 bps (±24.6 ppm)

STS-1e/STM-0e

51840000 ±1276 bps (±24.6 ppm)

E4

139264000 ±2730 bps (±19.6 ppm)

STS-3e/STM-1e

155520000 ±3826 bps (±24.6 ppm)