Smart Mode

116

IQS-8100 Series Transport Blazer

Using SmartMode for Alarm/Error Monitoring

Range indicates the minimum and maximum optical power
values necessary to meet the standard BER for the test interface.

Power indicates the power level of the input signal in dBm. The
background color of the Power field indicates the input presence
as follow:

Frequency (bps) indicates the received signal frequency in bps.

Note: The port statistics are only refreshed (live) when the alarm scan is running.

3. To see the Section/RS/Line/RS/MS analysis, press the signal button and

press the Section/Line/RS/MS tab.

Background

color

Description

Green

Power level in-range.

Yellow

Power level out of operational range.

Red

Power level crosses the “Close-to-damage”

threshold.

Grey

LOS or invalid operational range value reported by

the optical device (SFP/XFP).