Error/alarm rx, Configuration, Alarm analysis – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 413

background image

Ethernet Tabs

SONET/SDH Application

399

Error/Alarm RX

Error/Alarm RX

The alarm/errors statistics are gathered on all received frames,
independently of the destination MAC address.

Press TEST, Ethernet / Gb Ehternet / 10G Ethernet, and Error/Alarm RX.

Configuration

Oversize Monitoring: Enables the monitoring of the Oversize error.

Alarm Analysis

³

Link Down: Indicates that the Ethernet connection is down. The
Ethernet connection is down when there is a local or a remote fault
condition.

³

Remote Fault: Indicates that a Remote Fault event is detected.

³

Local Fault: Indicates that impairments such as LOS, AIS, and OCI are
affecting the traffic. Available with Ethernet and 10G Ethernet only.

Note: Alarms/Errors are updated only during test execution.

Ethernet and
10G Ethernet

Gb Ethernet