beautypg.com

Row 4, Default – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 199

background image

OTN Tabs

SONET/SDH Application

185

ODU OH TX

Row 4

³

GCC1: The two General Communication Channel-1 bytes are
configurable from 00 to FF. The default value for each byte is 00.

³

GCC2: The two General Communication Channel-2 bytes are
configurable from 00 to FF. The default value for each byte is 00.

³

APS/PCC: The Automatic Protection Switching / Protection
Communication Channel overhead bytes are defined in the ITU-T
G.709 standard. These bytes are configurable from 00 to FF. The default
value is 00.

³

RES: The six Reserved (RES) bytes are configurable from 00 to FF. The
default value for each byte is 00.

Default

Reverts the overhead bytes to their default values.