beautypg.com

EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 119

background image

Creating and Starting a Test Case

SONET/SDH Application

105

Typical Test Cases

4c. VCG configuration:

Enable LCAS: Allows enabling LCAS
configuration. This setting is disabled by default.

Add Member(s) at Start: Allows enabling by
default all the new members that will be
selected for this VCG group. The activation can
be done individually for the Source and Sink.
This default setting can further be overwritten
individually for each member that will be added to the group (See
Auto Add at Startup on page 106). All members enabled will be
automatically added (applied) when the test is started. This
setting is disabled by default unless otherwise set from the LCAS
Auto-Add at Startup
on page 542.

Remote DUT: Non-LCAS Specifies that the remote device
connected to the IQS-8115/20/30 is LCAS (when disabled) or
Non-LCAS (when enabled).

Group Size indicates the type and size of the VCG members as
well as the bandwidth used by the VCG group.

4d. For LOP VCG-1, press a first STS-1/AU timeslot, press Next, select

the VT/TU mapping, press every LOP timeslot that need to
become VCG member of the selected STS-1/AU timeslot.

4e. For HOP VCG-1, press a first timeslot that need to become a VCG

member.