beautypg.com

EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 523

background image

Common Tabs

SONET/SDH Application

509

Performance Monitoring (PM)

³

DM (Degraded Minutes) (G.821 only): A Degraded Minute is the
number of minutes in which the estimated error rate exceeds 10

-6

but

does not exceed 10

-3

. DM is determined by collecting all of the

Available Seconds, removing any SES grouping the result in 60-second
long groups and counting a 60-second long group as degraded if the
cumulative errors during the seconds present in the group exceed 10

-6

.

³

SEP (Severely Errored Period) (G.828 only): A sequence between 3 to
9 consecutive SES. The sequence is terminated by a second which is
not a SES.

³

SEPI (Severely Errored Period Intensity) (G.828 only): Gives the count
of SEP events in available time, divided by the total available time in
seconds.