beautypg.com

Frequency – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 163

background image

Port Tabs

SONET/SDH Application

149

Port TX (Optical Interfaces)

Frequency

Note: Frequency offset is not available when Through mode is selected.

³

Frequency Offset (ppm): Allows entering a positive or a negative
frequency offset in ppm. The default setting is 0.

³

Actual Frequency (bps): Indicates the frequency (actual frequency +
Frequency offset) used for transmission.

³

Nominal Frequency (bps): Indicates the nominal frequency of the
signal.

³

On/Off button: Allows enabling the frequency offset generation. This
setting is disabled (Off) by default.

Interface

Frequency Offset

a

a.

The frequency offset range is guaranteed for a source signal at 0 ppm offset. In the

event that the source signal already has an offset then, the output signal may

exhibit an offset larger than the range specified.

Nominal Frequency

OC-3/STM-1

± 50 ppm

155520000 bps

OC-12/STM-4

± 50 ppm

622080000 bps

OC-48/STM-16

± 50 ppm

2488320000 bps

OTU1

± 50 ppm

2666057143 bps

OC-192/STM-64

± 50 ppm

9953280000 bps

OTU2

± 50 ppm

10709225316 bps

OTU1e

± 115 ppm

11049107143 bps

OTU2e

± 115 ppm

11095727848 bps

OTU1f

± 115 ppm

11270089286 bps

OTU2f

± 115 ppm

11317642405 bps

OC-768/STM-256

± 50 ppm

39813120000 bps

OTU3

± 50 ppm

43018413559 bps