OTU RX

OTU RX

Press TEST, OTUk, and OTU (under OTUk RX).

Configuration

Note: See OTU TX on page 157 for more information on Enable Scrambler.

Alarm Analysis

Possible alarms that can be detected are:

³

LOF (Loss Of Frame): LOF is declared when OOF is present for at least
3 ms.

³

OOF (Out-Of-Frame): OOF is declared when FAS (bytes 3, 4, and 5) are
in error for at least 5 consecutive OTU frames.

³

LOM (Loss Of Multiframe): LOM is declared when OOM is present for
at least 3 ms.

³

OOM (Out-Of-Multiframe): OOM is declared when MFAS are in error
for at least 5 consecutive OTU frames.

³

OTU-AIS (OTU - Alarm Indication Signal): OTU-AIS is declared when
polynomial number 11 (PN-11) is over all OTU frame bits including FAS
and MFAS for at least 3 consecutive 8192 bit-interval.