background image

DSn Tabs

SONET/SDH Application

289

FDL PRM TX

³

PRM Bit Events: Allows the activation of the following PRM bit events.
All PRM bit events are disabled by default.

G1: CRC error event = 1
G2: 1 < CRC error event ≤ 5
G3: 5 < CRC error event ≤ 10
G4: 10 < CRC error event ≤ 100
G5: 100 < CRC Error Event ≤ 319
G6: CRC error event ≥ 320
R Bit (Reserved - Default value is 0)
SE: Severely errored framing event ≥ 1
FE: Frame synchronization bit error event ≥ 1
LV: Line code violation event ≥ 1
SL: Slip event ≥ 1
LB: Payload loopback activated
U1: Bit
U2: Bit

Statistics

Count indicates the number of PRM messages sent.