Alarm generation – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual
Page 450
Next-Generation Tabs
436
IQS-8100 Series Transport Blazer
GFP Channel TX
Alarm Generation
Allows the generation of client management frames alarms.
Note: The PTI value will be automatically set to 100 when generating a CMF
alarm.
³
Type
LOCS (CSF-Loss of Client Signal): Generates a LOCS by setting the UPI
field to “0000 0001”.
LOCCS (CSF-Loss of Client Character Synchronization): Generates a
LOCCS by setting the UPI field to “0000 0010”.
User Defined CMF (Client Management Frame): Allows to set the
User-defined UPI for the CMF value. Refer below for more information
on User-defined UPI field.
FDI (Forward Defect Indication): Generates a client FDI by setting the
UPI field to “0000 0100”. Not available with GFP-T.
RDI (Reverse Defect Indication): Generates a client RDI by setting the
UPI field to “0000 0101”. Not available with GFP-T.
DCI (Defect Clear Indication): Generates a client DCI by setting the UPI
field to “0000 0011”. Not available with GFP-T.
³
Period: Allows to set the alarm period associated with the client
management frames. Choices are from 10 ms to 1200 ms. The default
setting is 100 ms.