beautypg.com

EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 525

background image

Common Tabs

SONET/SDH Application

511

Performance Monitoring (PM)

For M.2100 ISM: Gives the count of the seconds within which
anomalies (frame bit errors, CRC block errors, etc.) are ≥ Y or at least
one defect occurred. Y depends on the type of DSn/PDH signal as
described in the following table.

³

BBE (Background Block Error) (G.828 and G.829 Line): Gives the count
of Errored Blocks not occurring as part of an SES.

Signal

SES Threshold

DS1 (SF)

8 frame bit errors (Near-End)

DS1 (ESF)

320 CRC-6 block errors (Near-End) 320 CRC-6 block errors

(Far-End, if FDL enabled)

E1 (Framed without CRC-4) 28 frame bit errors (Near-End)
E1 (Framed with CRC-4)

805 CRC-4 block errors (Near-End) 805 E-bit errors

(Far-End)

DS3 (M13)

2444 P-bit errors (Near-End) or 5 F-bit errors (Near-End)

DS3 (C-bit Parity)

2444 P-bit errors (Near-End) or 5 F-bit errors

(Near-End) 2444 FEBE errors (Far-End)

E2 (Framed)

41 frame bit errors (Near-End)

E3 (Framed)

52 frame bit errors (Near-End)

E4 (Framed)