Error/Alarm RX

Error Analysis

³

FCS: The number of received frames with an invalid FCS.

³

Jabber/Giant: The number of received frames larger than 1518 (no
VLAN tag), or 1522 (1 VLAN tag) bytes with an invalid FCS.

³

Oversize: The number of received frames larger than 1518 (no VLAN
tag), or 1522 (1 VLAN tag) bytes with a valid FCS. Oversize error
analysis is only available when Oversize Monitoring is enabled (see
page 399).

³

Runt: The number of received frames that are smaller than 64 bytes
with an invalid FCS.

³

Undersize: The number of received frames smaller than 64 bytes with
a valid FCS.

For Gb Ethernet only:

³

Symbol: A Symbol Error is declared when an invalid code-group in the
code is detected.

³

Idle: An Idle Error is declared when an error is detected between the
end of a frame and the beginning of the next frame.

³

False Carrier: A False Carrier is declared when data is being received
with no valid start of frame.

For Ethernet and 10G Ethernet only:

³

Block: The number of frames received with an errored block
condition. Not available with 10G Ethernet in GFP.

Total Error Count: Indicates the total number of errors including all the
above errors at the exception of Oversize when the Oversize Monitoring
check box is not selected.