Creating and Starting a Test Case
SONET/SDH Application
95
Typical Test Cases
5b. For ODU1 and ODU0, select a tributary slot,
choices are:
For ODU1 in ODU2: 1 of 4 OPU2 tributary slots
For ODU0 in ODU2: 1 of 8 OPU2 tributary slots
For ODU0 in ODU1: 1 of 2 OPU1 tributary slots.
Select ODU TCM (TCM1 to TCM6) layers as
required. The Tributary Port associated to the
selected tributary slot is displayed.
5c. For ODUflex, select the OPU2 tributary slots
(1 to 8), enable ODUflex TCM (TCM1 to TCM6)
layers as required, and select the Tributary Port
number (1 to 8) that will be associated to the
selected tributary slots. The current bandwith
and the number of selected tributary slots are
displayed.
5d. For OC-x and STM-x, press Next.
5e. For STS/VT/AU/TU mapping level, select the
timeslot and enable TCM when required.
5f. For GFP, the UPI and the EXI parameters are
preset and not configurable. GFP is available in
Coupled test mode only. Refer to GFP Frame TX
on page 432 for more information.
5g. For 10G Ethernet, Gb Ethernet, or Ethernet in
GFP, set the Ethernet parameters. Refer to
Configuration on page 393 for more information.
5h. Press Next or Finish.