OTN Tabs

162

IQS-8100 Series Transport Blazer

OTU TTI TX

OTU TTI TX

Press TEST, OTUk, and OTU TTI (under OTUk TX).

SM TTI Trace

Injected Message

³

SAPI allows editing the Source Access point Identifier message to be
generated (TTI bytes 1 to 15). A maximum of 15 characters are
allowed. The default setting is EXFO OTU SAPI. The TTI byte 0 is set to
NULL (all 0’s).

³

DAPI allows editing the Destination Access point Identifier message to
be generated (TTI bytes 17 to 31). A maximum of 15 characters are
allowed. The default setting is EXFO OTU DAPI. The TTI byte 16 is set
to NULL (all 0’s).

³

Operator Specific allows editing the Operator Specific message to be
generated (TTI bytes 32 to 63). A maximum of 32 characters are
allowed. The default setting is EXFO OTU OPERATOR SPECIFIC.

³

Overwrite: Available with OTN Intrusive through mode only
(optional). The Overwrite check box when selected, generates the
defined SM TTI Trace message. Overwrite is not available on
IQS-8105/IQS-8115.