Tools Tab

552

IQS-8100 Series Transport Blazer

Script Tab

Edit

Lists the content of the current script and allows its edition. Users with
writing knowledge of Visual Basic .NET (Visual Basic) programming
language will be able to customize their scripts by inserting delays for
example. Note that delays are not automatically inserted during recording.

Output

Gives status of the running script.

File

Allows loading, saving, and generating a new script file.

Note: The default directory for the script files is:

d:\IQS Manager\User Files\SonetSdhAnalyzerG2\Scripts

Press New to create a new script and clear the one on the Edit tab if

exist. Type a new file name in the File name field and press Save.
Press Load and select a script file and press Load.

Press Save and select a name for this script file followed by the scp

extension and press Save. The scp extension is automatically

added when omitted.