beautypg.com

Error injection – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 390

background image

PDH Tabs

376

IQS-8100 Series Transport Blazer

E1/2M TX

Error Injection

Allows manual or automated error injection.

³

Type: The following error types are available with both manual and
automated injection modes. Choices are FAS, CRC-4, and E-bit. The
default setting is FAS.

Note: Available choices depend on the selected framing.

³

Amount: Select the amount of error to be generated. Choices are 1
through 50. The default setting is 1.

³

Send button: Press Send to manually generate error(s) according to
the Error Type and the Amount of Errors selected.

³

Rate: Press Rate to select the injection rate for the selected error. The
rate must be within the minimum and maximum values specified. The
default setting is 1.0E-2.

³

Continuous: Generates the selected error to its theoretical maximum
when the Continuous check box is selected. The Continuous check
box is cleared by default.

³

On/Off button: The On/Off button is used to activate/deactivate the
selected automated error at the rate specified or at its theoretical
maximum rate when the Continuous check box is selected. This
setting is disabled (Off) by default.