beautypg.com

Standard – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 519

background image

Common Tabs

SONET/SDH Application

505

Performance Monitoring (PM)

Standard

Select the desired standard from the list. The default setting is G.826 ISM
for IQS-8105/15/20/30 and G.828 ISM for IQS-8140. Choices are G.821,
G.826 ISM

1

, G.828 ISM, G.829 ISM, M.2100 ISM

1

, M.2100 OOSM, and

M.2101 ISM.

Note: G.821 and M.2100 OOSM are only available when receive Live Traffic from

the Pattern RX on page 409 is not activated.

Standard’s availability

1. Not available on the IQS-8140.

Analyzed Signal

G.821 G.826

ISM

1

G.828

ISM

G.829

ISM

M2100

ISM

1

M2100

OOSM

M2101

ISM

Pattern

X

X

DS1/DS3 / E1/E2/E3/E4

X

X

STS-Ne/VTn / STM-Ne/AU-n/ TU-n

X

X

OC-N Section / STM-N RS

X

OC-N Line / STM-N MS

X

X