beautypg.com

Default button – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 457

background image

Next-Generation Tabs

SONET/SDH Application

443

GFP OH TX

³

Extension Header

Note: CID and Spare are only available when EXI from GFP Frame TX on

page 432 is set to Linear.

³

CID (Channel IDentifier) allows to overwrite the communication
channel used for the signal transmission set from GFP Channel TX
on page 435. Choices are from 00000000 through 11111111 (0 to
255). The default setting is 00000000.

³

Spare allows to set the extension header Spare field. Choices are
from 00000000 through 11111111 (0 to 255).

Default Button

Click on Default to return to default configuration defined in the test case
for the selected GFP frame type (Frame Type Selection). The Default button
is only available when at least one overwrite is active.

0001 0010 Framed DVD-ASI

Reserved for future use

0001 0011 Framed 64B/66B Ethernet
0001 0100 Framed 64B/66B Ethernet Ordered Set
0001 0101

through

1110 1111

Reserved for future standardization

1111 0000

through

1111 1110

Reserved for proprietary use

UPI

Description for PTI = 000

Description for PTI = 100