EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual
Page 212
OTN Tabs
198
IQS-8100 Series Transport Blazer
OPU TX
Note: Codes not listed in the previous table are reserved for future
standardization (Reserved For International Standardization).
Note: The Code field is automatically updated when the Injected payload Type is
changed and vice versa.
GFP Into Extended OPU2
09
0000
1001
OC-3/STM1 mapping inot ODU0
0A
0000
1010
OC-12/STM-4 into ODU0
0B
0000
1011
FC-100 into ODU0
0C
0000
1100
FC-200 into ODU1
0D
0000
1101
FC-400 into ODUflex
0E
0000
1110
FC-800 into ODUflex
0F
0000
1111
Bit Stream with Octet Timing
10
0001
0000
Bit Stream Without Octet Timing
11
0001
0001
ODU Multiplex with ODTUjk
20
0010
0000
ODU Muliplex with ODTUk.ts/ODTUjk
21
0010
0001
Not Available
b
55
0101
0101
Reserved Codes for Proprietary Use
c
80
1000
0000
NULL Test Signal
FD
1111
1101
PRBS Test Signal
FE
1111
1110
a.
Selecting Reserved for International Standardization will use the hexadecimal code 00 but, all codes
not listed in the previous table at the exception of those cover in notes b and c are reserved for future
standardization.
b.
Selecting Not Available will use the hexadecimal code 55 but, 66 and FF are also Not Available payload
types.
c.
Selecting Reserved Proprietary will use the hexadecimal code 80 but, all codes from 80 to 8F are
reserved proprietary payload types.
Payload type
Hex Code
MSB
1234
LSB
5678